Chat
Contact us
Close contact box
Connect ID #
736 504 428 4
Connect ID #
736 504 428 4
Don't wait on hold. We'll call you back when it's your turn to talk with the next available .
Please enter your name  
Please enter your phone number  
Please enter a message  

Calls may be recorded for training and quality control purposes.

We are located in Virginia USA.

Thank you. We will be calling you .
We're sorry. We have encountered a problem.

AtlasIED AA100PHD 4-input commercial mixer/amplifier — 100W x 1 at 70V

Item # 978A100PHD

The Atlas AA100PHD provides power and signal distribution for background music and paging in a medium-sized office...

The Atlas AA100PHD provides power and signal distribution for background music and paging in a medium-sized office...

California customers:
Please click here for your Proposition 65 warning.

Item # 978A100PHD

Ships free today

In stock
$720.99

Other options

About the AtlasIED AA100PHD

Eric A.

Music, paging, and more

The Atlas AA100PHD provides power and signal distribution for background music and paging in a medium-sized office or business.

Get started with
a free system design

After we gather your information, we'll send you a detailed system plan. It will include a link to a pre-filled shopping cart. Ordering is easy, and delivery is fast.

Give us a call
1-800-315-2758
Submit a design request
Tell us about your space

Music, paging, and more

The Atlas AA100PHD provides power and signal distribution for background music and paging in a medium-sized office or business.

Four inputs let you play different sources of music and make announcements. Set the AA100PHD so the music mutes when the microphone is on or when its button activates the remote trigger. You can also route any combination of inputs to a Zone 2 output for a second set of speakers or for music on hold in a telephone system.

Smart enough to help you set up your system

Why do we say this mixer amplifier is smart? Well, because it has a PHD after its name, of course. We're talking about the Atlas AA100PHD, so that acronym stands for Push Here Diagnostic. Press the PHD button, and the unit will check to see if you've exceeded the recommended wattage for the amp or made an error in selecting impedance somewhere along the line. It's an amazing safety feature that can save you from damaging your equipment.

See what our satisfied customers have to say.

READ LESS

Product highlights:

  • amplified 4-channel mixer for commercial audio distribution
  • output: 100 watts RMS x 1 at 25 volts, 70.7 volts, or 4 ohms
  • 3 unbalanced stereo pair line inputs
  • 2 balanced inputs with phantom power
  • assignable zone 2 output
  • Push Here Diagnostic® (PHD) automatically verifies that attached speakers' tap settings do not exceed the amplifier's rated power
  • remote and voice-activated mute
  • individual input volume controls
  • bass control: ±6dB at 100 Hz (shelving)
  • treble control: ±6dB at 10K Hz (shelving)
  • "Pre Out" and "Amp In" loop plus two preamp outputs for external processors or amplifiers
  • rear panel unswitched AC receptacle to power external gear
  • 8-5/16"W x 3-11/16"H x 10-7/8"D
  • warranty: 3 years
  • MFR # AA100PHD

What's in the box:

  • 4-Input Mixer Amplifier with attached 6' AC power cord (3-prong plug)
  • Owner's Manual
  • AA & PA Series Accessories sheet

Customer reviews for AtlasIED AA100PHD

Loading reviews...

Average review:

5.0 out of 5 stars
5 reviews

Thanks for submitting your review

Filter by rating

Customer photos

Customer provided image, click to load a larger version.
Customer provided image, click to load a larger version.

Sort reviews

Sort by:
Items per page:
View page:

Verified customer (What's this?)
Verified employee review (What's this?)

Reviewed on Samsung.com

This review was collected as part of a promotion

Pros:

Cons:

Crutchfield response
Customer provided image, click to load a larger version.
<< >>

More details on the AtlasIED AA100PHD

Russ B.

Product Research

Features

Overview: The Atlas Sound AA100PHD is a four-input, 100-watt mixer-amplifier that is ideal for small to medium-sized retail, industrial, and commercial businesses that use background music, distributed paging, and music-on-hold. It can also be used for speech privacy systems. The amp can accommodate a variety of input sources, and can power a 4Ω speaker load, or 25V and 70.7V commercial speaker systems.

Push Here Diagnostic: This AAPHD series mixer amp includes a patent pending automatic system test to check the connected speaker lines for wiring and impedance errors. The front panel Push Here Diagnostic (PHD) button automatically verifies that the attached speakers' tap settings do not exceed the amplifier's rated power, that no speakers are mistakenly tapped at 8Ω, and the speaker wire is not shorted anywhere.

Inputs: The AA100PHD has four input channels with independent level controls on the front panel:

  • The Channel 1 input has a removable Phoenix (Euro Block) connector with +, -, and G terminals for balanced microphone or line level signals. DIP switches on the rear panel let you select mic or line input, and turn on Phantom power for condenser-type microphones. The Channel 1 input signal can be used to trigger or activate a mute command. A VOX Mute Sensitivity Control, located beside Input 1, can adjust the sensitivity of the mute circuitry. This can be used to mute background music on another input channel when a paging announcement is made on Input 1.
  • The Channel 2 input can accept more than one type of audio signal, but only one at a time. The input has a 3-conductor Phoenix connector for a balanced mic or line source, and a stereo 3.5mm mini-jack. Like Channel 1, you can select the type of input and turn on Phantom power for condenser mics through the DIP switches on the rear panel. The stereo 3.5mm input is summed, and can be used for connecting a CD or DVD player or MP3 player.
  • Channels 3 and 4 are stereo RCA summing inputs for connecting a CD or DVD player.

Speaker Output: The amplifier has a removable Phoenix connector for the speaker outputs. There are connections for a 4Ω direct-coupled speaker load, or 25V and 70V transformer-coupled speaker systems. The Phoenix connector will accept up to 12-gauge wire.

Zone 2 Output: The AA100PHD features a Zone 2 output that gets its signal from a selected input for music or messaging on hold applications. The Zone 2 terminal is an unbalanced 600Ω output with a maximum level of 1.0VRMS. A dedicated Zone 2 volume control is provided on the rear panel. The removable 2-conductor Phoenix connector accepts up to 18-gauge wire. Four DIP switches are provided for selecting an input for Zone 2.

Pre Out Jacks: The Pre Out (RCA) connector allows you to feed a signal to another power amplifier or external audio device. An effects loop can be created by connecting the Pre Out jack to an equalizer or other device, and then back out to the Amp In connector.

Amp Input: The Amp In connector can be used to convert the AA100PHD into a slave amp. When a line level signal is connected to this input, the internal connection between the preamp and internal power amp is broken. The AA100PHD becomes just a power amplifier, amplifying audio signal applied to the Amp In (Pwr In) connector.

Front Panel Controls: The front panel includes a master power switch (push button), a Master Level control, and rotary volume controls for Inputs 1 through 4. The PHD switch is a flush-mounted button that requires a small tool with a point to activate the self-diagnostic test (See Push Here Diagnostic section above). There are status LEDs for Signal, Peak, Limit, and Power.

Bass/Treble Controls: Separate rotary bass and treble controls are provided on the back panel. Normally set at the 12:00 position, the bass control lets you adjust bass frequencies from -6 dB to + 6dB at 100 Hz, while the treble control adjusts treble frequencies from -6 dB to +6 dB at 10 kHz.

Remote Level Control: The Remote Level Control port lets you connect an optional Atlas Sound WPD-RISRL or WPD-VC10K level control. You can control the level of Input 1 or Inputs 2, 3, and 4 together. When a remote level control is connected, the system's maximum levels should be set using the front panel level controls, and use the remote potentiometer as an attenuator from the maximum levels set.

Remote Input Select (RIS): With the optional WPD-RISRL wall-mounted remote input selector and volume control, you can select inputs 2, 3, or 4, but not input 1, and adjust the volume. This is accomplished without having to run an audio signal from the amplifier to the selector, which prevents picking up interference. The WPD-RISRL connects to the amplifier through the RIS and Remote Level connections on the amp, with a maximum range of 200 feet.

DIP Switches: The versatile AA100PHD has two sets of DIP switches on the rear panel that allow the amp to be configured in many ways. One set of DIP switches selects the input for Zone 2, while the other set allows you to choose which inputs are muted when a signal is present on Input 1, selects Mic or Line as the input type for Input 1 and Input 2 independently, turns on Phantom Power for a Condenser Mics connected to Input 1 or 2, and activates the Remote Input Select circuits.

Specifications:

  • Frequency Response: 80Hz - 15kHz (+/-3dB; 1% THD)
  • Output Power: 100 watts RMS
  • Dimensions: Width: 8.25", Height: 3.681", Depth: 10.875"
  • Weight: 13 pounds 2 ounces

Loading accessories...

Customer Q&A

Loading articles...

Looking for more?

Check out the next model in this lineup.


Adding...
AtlasIED AA200PHD

AtlasIED AA200PHD

6-input commercial mixer/amplifier — 200W x 1 at 70V
$926.99
Add to cart
Something went wrong. Please for help purchasing this item.

Get more inputs and output power

The AtlasIED AA200PHD offers these features:
  • amplified 6-channel mixer for commercial audio distribution
  • output: 200 watts RMS x 1 at 25 volts, 70.7 volts, or 4 ohms
  • 4 balanced inputs with phantom power
Compare the sound